You can usually tell when a site has a noise problem before anyone gets a meter out. Two labourers are shouting at each other across a skip, the breaker has been going since half seven, and the ear defenders are hanging round someone's neck because "it's only for a minute". The Noise at Work Regulations exist because those minutes add up, and the hearing they cost doesn't come back.

The Control of Noise at Work Regulations 2005 are the law that requires employers in Great Britain to assess and control workers' exposure to noise. They set three trigger points for daily or weekly exposure: a lower exposure action value of 80 dB(A), an upper exposure action value of 85 dB(A) and an exposure limit value of 87 dB(A), with matching peak values of 135, 137 and 140 dB(C). Cross each line and more duties apply, from risk assessment and training through to hearing protection zones and health surveillance.

This guide covers what the regulations say, what each value means in practice, and how to deal with noise properly in your risk assessments and method statements. If your worry is hand-arm vibration from the same breakers and grinders, that has its own regulations, and we've covered it in our HAVS assessment guide.

What are the Noise at Work Regulations?

The Control of Noise at Work Regulations 2005 (SI 2005/1643) came into force for most sectors on 6 April 2006, and for the music and entertainment sectors on 6 April 2008. They sit under the Health and Safety at Work etc Act 1974, so the Act's general duties still apply alongside them. For the wider picture, see our guide to the Health and Safety at Work Act 1974.

The regulations protect people at work: your own employees and other workers affected by your work activities. They don't cover members of the public exposed to noise from your work, although HSE points out that section 3 of the 1974 Act may still apply in those cases.

In broad terms the regulations require you to:

  • assess the risk from noise (regulation 5)
  • eliminate noise at source or reduce it as far as reasonably practicable (regulation 6)
  • provide hearing protection and set up hearing protection zones where needed (regulation 7)
  • maintain noise-control equipment and hearing protection, and make sure it's used (regulation 8)
  • provide health surveillance where there's a risk to health (regulation 9)
  • give workers information, instruction and training (regulation 10)

Noise at work regulations action values and limits

Regulation 4 sets the numbers. There are two measures. Daily or weekly personal noise exposure (written LEP,d or LEP,w) is the noise "dose" over a working day or week, combining how loud it is with how long someone is exposed. Peak sound pressure (LCpeak) captures single loud bangs, such as a cartridge tool firing or a hammer striking steel.

  • Lower exposure action value: 80 dB(A) daily or weekly exposure, or 135 dB(C) peak sound pressure.
  • Upper exposure action value: 85 dB(A) daily or weekly exposure, or 137 dB(C) peak sound pressure.
  • Exposure limit value: 87 dB(A) daily or weekly exposure, or 140 dB(C) peak sound pressure.

There's one detail that catches people out. When you compare exposure with the action values, you ignore any hearing protection. The exposure limit values are different: they take account of the reduction your hearing protection gives. Put simply, the limit values are the line nobody should cross even with ear defenders on.

Weekly averaging is allowed where exposure varies a lot from day to day, for example a fitter who spends one day on a breaker and the rest of the week on quieter work. HSE says you should discuss any proposal to average exposure over a week with safety or employee representatives.

What you must do at each level

At or above the lower exposure action value (80 dB(A) or 135 dB(C))

Once workers are likely to be exposed at or above the lower value, you must provide hearing protection to employees who ask for it, and give information, instruction and training. HSE's leaflet INDG362 says that should at least cover people's likely exposure and the risk to their hearing, what you're doing about it, where to get hearing protection and how to use it, how to report defects, their own duties and your health surveillance arrangements.

At or above the upper exposure action value (85 dB(A) or 137 dB(C))

Above the upper value, the duties get firmer, and health surveillance comes in (more on that below). You must reduce exposure through a planned programme of noise control, not just hand out earplugs. Hearing protection must be provided and you must make sure it's worn fully and properly. You must also mark hearing protection zones: areas where access is restricted and wearing hearing protection is compulsory. Our guide to hazard symbols and signs covers the blue mandatory signs you'd use to mark them.

The exposure limit value (87 dB(A) or 140 dB(C))

Nobody should be exposed above the limit values, taking their hearing protection into account. If your assessment shows someone could be, you need to change the work: a different method, less time on the task, more distance or better protection. Meeting the limit values doesn't end your duty either. HSE is clear that the duty to reduce noise risks as far as reasonably practicable is separate from staying under the limits.

Do you have a noise problem? HSE's quick checks

HSE says you'll probably need to do something about noise if any of these apply:

  • the noise is intrusive, about as noisy as a busy road, a vacuum cleaner or a crowded restaurant, for most of the working day
  • people have to raise their voices to hold a normal conversation when about 2 metres apart for at least part of the day
  • people use noisy powered tools or machinery for more than half an hour a day
  • you work in a sector known for noisy tasks, such as construction, demolition or road repair
  • there are impact noises, such as hammering or pneumatic impact tools, or explosive sources like cartridge-operated tools

If any apply, do a noise risk assessment. Think about safety as well as hearing: noise and ear defenders can mask reversing alarms, radio calls and shouted warnings, so work around mobile plant needs extra thought.

How to do a noise risk assessment

A noise risk assessment isn't just a set of meter readings. HSE says measurements may not even be necessary, and its construction FAQs say many site assessments can be prepared without measuring equipment, provided you use reliable information and realistic estimates. Your assessment should:

  1. Identify where there's a risk from noise and who's likely to be affected, including risks to safety as well as hearing.
  2. Estimate each group's daily exposure and peak exposure, using manufacturers' data, HSE guidance, information from similar work or your own measurements. HSE's online noise exposure calculators help with the sums.
  3. Compare those estimates with the action and limit values.
  4. Decide what you need to do: noise control, hearing protection, zones, health surveillance, training.
  5. Record the findings and an action plan, with who is responsible and by when.

HSE says you should review the assessment when things change, for example new plant, a different method or longer shifts on a noisy task, and not leave it more than about two years without checking whether a review is needed. If you want to see how a finished assessment reads, have a look through our risk assessment examples on our blog.

Controlling noise: hearing protection comes last

The regulations follow the usual hierarchy. Ear defenders are a backstop, not the plan. HSE's construction guidance puts it plainly: it isn't acceptable to rely on hearing protection alone. Work through the options in this order:

  • Eliminate: can the noisy task be designed out? A block splitter instead of a cut-off saw, or bored piles instead of driven ones.
  • Substitute: choose lower-noise tools and plant when you hire or buy, and compare manufacturers' noise data between models.
  • Engineering controls: silencers, mufflers, damping, acoustic screens and enclosures around generators and compressors.
  • Organisational controls: keep people away from noisy work, rotate tasks, limit time on the tool, and schedule the loudest work when fewer trades are nearby.
  • Hearing protection: issue suitable protectors, train people to fit them, and supervise their use.

When you do issue hearing protection, pick the right level. HSE warns against protectors that take the level at the ear below 70 dB, because over-protection makes it hard to hear warnings and colleagues, and people then take them off. Check that protectors work with hard hats, eye protection and masks, keep seals and headbands in good condition, and make sure people know they have a duty to report defects. Our guide to the PPE at Work Regulations covers selection, fit and training in more depth.

Under regulation 8, anything you provide to control noise has to be maintained. A split silencer or a generator canopy left open all day can quietly undo your controls.

Health surveillance: hearing checks

Where health surveillance is needed, HSE says it usually means hearing checks once a year for the first two years of exposure, then every three years. Checks may need to be more frequent if a problem is found or the risk is high. Ideally, take a baseline check before someone starts noisy work.

The checks should be done by someone with the right training, and the results reviewed by a suitable doctor, nurse or audiologist. You'll receive fitness-for-work information, but you should only see details of an individual's hearing damage with their consent. Keep health records of the outcomes separate from confidential medical results. Where damage is found, review your assessment and controls too.

Noise on construction, security and FM sites

Construction and demolition

HSE lists concrete breakers, pokers and compactors, sanders, grinders, disc cutters, hammer drills, chipping hammers, cartridge-operated tools, scabblers and needle guns among the usual culprits, plus heavy plant. On a demolition job or a groundworks package several of these run at once, so exposure depends on where people stand as much as on their own tool. A labourer working a few metres from a breaker can pick up a significant dose without touching a tool.

Practical steps that work on real jobs include setting cut-off saws up in a screened cutting station away from the main work area, fitting acoustic canopies to generators and compressors, and planning breaking-out for times when fewer trades are nearby. Put them in the method statement so they actually happen. There's more on planning site controls in our construction section.

Facilities management

FM teams meet noise in plant rooms, boiler houses, generator tests, grounds maintenance and when using floor scrubbers or pressure washers. Plant rooms are a common place for a permanent hearing protection zone, with a sign on the door and defenders on a hook outside. The same approach works for any fixed noisy plant.

Security and events

Door supervisors and stewards at live music venues work in exactly the environment the 2008 music and entertainment start date was about. HSE's guidance for that sector, Sound Advice (HSG260), covers it in detail. Security staff still need to hear radio calls and people in distress, so protector choice matters. Protection that cuts noise without blocking speech, or that works with an earpiece, may suit better than heavy defenders, so talk to your supplier. Our event security RAMS page shows how these tasks are usually set out.

Getting noise into your RAMS

Noise often appears in a RAMS as one line, "wear ear defenders", with nothing behind it. A better entry names the tools and plant, estimates exposure or explains how you know it's above or below the action values, lists the controls in hierarchy order, shows any hearing protection zones on the site plan, and says who checks that protectors are worn. Brief it at the start of the job, and use a toolbox talk to show people how to fit earplugs properly. A quick demonstration beats a paragraph of text.

How swiftRMS helps

swiftRMS is an AI tool that drafts RAMS for construction, security and FM teams. Describe the task, say a concrete breaker and disc cutter on a slab reduction, and it drafts a risk assessment and method statement that picks up noise as a hazard alongside the others, sets out controls in hierarchy order, and cites the relevant legislation, such as the Control of Noise at Work Regulations 2005. Our risk assessment software page explains how the drafting works.

The draft is a starting point, ready for review. Your competent person still needs to check the noise estimates against the tools and plant you're actually using, edit the controls for your site and approve the document before work starts, as regulations 3 and 7 of the Management of Health and Safety at Work Regulations 1999 expect. You can see what a draft looks like on our examples page.

If noisy work is on next week's programme, try a free RAMS preview with no signup. If it's useful, there's a 14-day free trial, and no card is needed.

Frequently Asked Questions

What are the three noise levels in the Noise at Work Regulations?

The lower exposure action value is 80 dB(A) daily or weekly exposure (135 dB(C) peak). The upper exposure action value is 85 dB(A) (137 dB(C) peak). The exposure limit value is 87 dB(A) (140 dB(C) peak), and it takes account of the hearing protection being worn. The two action values don't.

At what decibel level is hearing protection mandatory?

At or above the upper exposure action value of 85 dB(A) daily or weekly exposure, or 137 dB(C) peak, employers must provide hearing protection and make sure it's worn, and must mark hearing protection zones. Between 80 and 85 dB(A), hearing protection must be provided to employees who ask for it.

Do I need to measure noise on a construction site?

Not always. HSE says many construction noise risk assessments can be prepared without measuring equipment, as long as the exposure estimates are realistic and based on reliable information, such as manufacturers' data, HSE guidance and observations of how the work is actually done. Measure if you're unsure how close you are to an action value.

Who needs hearing tests at work?

Employers must provide health surveillance for employees likely to be frequently exposed above the upper exposure action values, and for anyone at particular risk, such as people who already have hearing loss. HSE says checks usually happen annually for the first two years, then every three years.

How often should a noise risk assessment be reviewed?

Review it whenever something changes that could affect exposure, such as new plant, a different method, longer shifts or a change in the controls available. HSE says you shouldn't leave it for more than about two years without checking whether a review is needed. Hearing check results that show damage are another reason to look again.

Is vibration covered by the same regulations?

No. Hand-arm and whole-body vibration fall under the Control of Vibration at Work Regulations 2005, which have their own action and limit values. The same tools often cause both, so it makes sense to assess them together. Our HAVS assessment guide, linked above, covers the vibration side.

Official Resources